Screw Type Air Cooled Chillers
| Product Type: | Textile Machinery >> Textile auxiliaries >> Industrial Air Conditioning | 
|
|---|---|---|
| Keyword: | Machinery,Industrial Air Conditioners | |
| Uses: | ||
| Origin: | China/Guangdong | |
| 
 If you are interested, please contact us! 
 | ||
| MOQ: | 1 Set/Sets | |
| Payment Terms: | L/C,T/T | |
| Delivery Time: | 300 Set/Sets per Month | |
- Type: Chiller
 - Place of Origin: Guangdong China (Mainland)
 - Model Number: AGS-200ADH ~ AGS-240ADH
 - Brand Name: ANGES
 
Screw type air cooled chillers have obtained several patents from countries of Europe and America and passed the ISO9001-2000.
Screw type air cooled chillers have obtained several patents from countries of Europe and America and passed the ISO9001-2000.
Technical Parameter of AGS-200ADH~240ADH Screw Type Air Cooled Chillers
Model Item  | AGS-200ADH  | AGS-240ADH  | ||||
nominal cooling capacity  | kcal/h  | 437740  | 550400  | |||
kw  | 509  | 640  | ||||
input power  | kw  | 168  | 205  | |||
max. running current  | A  | 500  | 550  | |||
power supply  | 3PH~380V 50HZ  | |||||
refrigerant  | type  | R22  | ||||
refrigerating circuit  | 2  | |||||
type of control  | thermostatic expansion valve  | |||||
compressor  | type  | semi-hermetic screw  | ||||
quantity  | 2  | |||||
start-up mode  | Y-  | |||||
capacity control  | 0-25-50-75-100  | |||||
condenser  | type  | air cooled type finned copper tube  | ||||
power (kw)  | 15  | 21  | ||||
cooling air flow (m3/h)  | 180000  | 235000  | ||||
evaporator  | type  | shell and tube  | ||||
quantity  | 1  | |||||
chilled fluid flow(m3/h)  | 88  | 110  | ||||
inlet and outlet pipe diameter (inch)  | 6  | |||||
safety protection  | compressor over temperature, over current, high and low pressure, over temperature,flow Switch, phase sequence, phase-missing, exhaust overheating, antifreezing  | |||||
net weight  | kg  | 4800  | 5500  | |||
running weight  | kg  | 5200  | 5950  | |||
Note: 1. nominal cooling capacity is according to: Inlet chilled fluid temperature: 12 Outlet chilled fluid temperature: 7 Inlet cooling air temperature: 35 Outlet cooling air temperature: 45 2. working range: The temperature range of chilled fluid is from 5 to 20; Temperature difference between inlet and outlet chilled fluid is from 3 to 8. Temperature difference between inlet and outlet cooling air is from 8 to 12. The chiller should be used while the ambient temperature at or below 35. 
 We reserve the right to modify the above dimensions or parameters without further notice.  | ||||||
| Company Name: | Shenzhen Anges Machinery Co., Ltd. | 
|---|---|
| Company Address: | No. 23, Limin Road, Gangtou Village, Bantian, Longgang District | 
| Zip: | 518129 | 
| Contact Person: | Mr. Sunny Li | 
| Telephone Number: | 86-755-28227245 | 
| Mobile: | |
| Fax Number: | 86-755-89582800,28227243 | 
| Email: | |